Ciria Report 108 Concrete Pressure On Formwork ((install)) 💎 🔔
Retarding admixtures extend the time before initial set. This effectively increases R/T ratio, raising pressure. The report suggests applying a temperature correction or using an "effective temperature" lower than the actual concrete temperature.
) based on concrete density, rate of rise, and temperature coefficients, distinguishing between wall and column applications. Detailed information on the 1985 report is available at CIRIA . Concrete Pressure Analysis per CIRIA 108 | PDF - Scribd ciria report 108 concrete pressure on formwork
To safely and economically design formwork today: Retarding admixtures extend the time before initial set